External connectors

Материал из WebHMI Wiki
Версия от 15:00, 12 июля 2017; Evgeniy.mozoliak (обсуждение | вклад) (Новая страница: «Connection of '''external WiFi antenna''' (RP-SMA type) border<br><br>»)

Перейти к: навигация, поиск

10-pin terminal connector "screw - type" - power, relays, RS-485
Wh bottom view cropped2.jpg

Pins assignment (from left to right):

1. Common24V
2. "+" line of 24В
3. Isolated gnd for LAN/WAN cable shields
4. Relay #1 N.O.
5. Common wire for relays #1,2
6. Relay #2 N.O.
7. N.C.
8 RS-485 signal ground
9 Data- (:B) RS-485
10 Data+ (:A) RS-485


Connection of RS-485 - refer to this.
Switching capacity for SSRs - max. current 100мА ~/=, max. voltage - up to 350V.
When using shielded Ethernet cable its shield will connect to GND terminal, which in his turn recommended to wire to ground for better noise protection.
Voltage input 24В +/- 10% (15%).


Connection of external WiFi antenna (RP-SMA type)

RP-SMA male.jpg







USB - для подключения дополнительных устройств (спецификация 2.0).
Ethernet разъемы LAN и WAN - назначение см.здесь.